PATENTED BY UNISLOT
FROM 47 TO 74% MORE FLOW FOR THE SAME FILTER VOLUME
The patented UNISLOT HIGH FLOW® system is a combination of two filters that occupy a similar space as a single filter tube. These filters can also be used in existing housings, both with and without backflush facilities.
All combinations are available in both filtration steams, both from inside to outside and from outside to inside.
We manufacture a wide range of gap openings, starting from at least 50 microns.
Advantages of the High Flow Filter®
- The filter space of the HIGH FLOW® system is significantly larger than that of a standard element. This increases the flow rate, making it unnecessary to opt for a larger housing.
- Due to the increase in flow, new filter systems can be manufactured more compactly.
- Existing filter systems can be equipped with our new HIGH FLOW® system.
- The conical design has the effect of creating equal pressure across the full length of the tube, which ensures that the full length is used for filtration instead of only the initial inlet surface.
- In backflush mode, the equal pressure allows for better removal of solid parts over the entire filter length, which improves power recovery.
CONICAL FILTER TUBE IN A CYLINDRICAL FILTER TUBE
The largest possible combinations of standard diameters available. Especially suitable for in-line systems.
Diam. Slot tube |
High Flow® filter (Diam. Slot tube + conical filter) |
Length |
Surface classical slot tube |
Surface new High Flow® filter |
Advantage |
57 mm |
57 + 40/30 mm |
250 mm |
0,045 m2 |
0,072 m2 |
60% |
70 mm |
70 + 50/40 mm |
250 mm |
0,055 m2 |
0,094 m2 |
71% |
70 mm |
70 + 50/30 mm |
500 mm |
0,110 m2 |
0,173 m2 |
57% |
85 mm |
85 + 50/30 mm |
500 mm |
0,134 m2 |
0,197 m2 |
47% |
110 mm |
110 + 65/40 mm |
500 mm |
0,173 m2 |
0,255 m2 |
47% |
110 mm |
110 + 90/55 mm |
720 mm |
0,249 m2 |
0,413 m2 |
66% |
110 mm |
110 + 90/40 mm |
1020 mm |
0,352 m2 |
0,560 m2 |
59% |
112 mm |
112 + 90/55 mm |
720 mm |
0,276 m2 |
0,440 m2 |
59% |
137 mm |
137 + 90/55 mm |
720 mm |
0,310 m2 |
0,474 m2 |
53% |
137mm |
137 + 90/40 mm |
1020 mm |
0,439 m2 |
0,647 m2 |
47% |
CONICAL FILTER IN A CONICAL FILTER
Has a different advantage in multi-filter backflush applications.
Diam. Conical filter |
High Flow® filter (Diam. Conical filter + Conical filter |
Length |
Surface classical slot tube |
Surface new High Flow® filter |
Advantage |
68/55 mm |
68/55 + 40/30 mm |
250 mm |
0,048 m2 |
0,075 m2 |
56% |
90/65 mm |
90/65 + 50/30 mm |
500 mm |
0,121 m2 |
0,184 m2 |
52% |
90/70 mm |
90/70 + 60/40 mm |
400 mm |
0,101 m2 |
0,164 m2 |
62% |
CYLINDRICAL FILTER TUBE IN A CONICAL FILTER TUBE
This will give the greatest increase in flow rate for a similar single filter composition.
Diam. Conical filter |
High Flow® filter (Diam. Conical filter + slot tube) |
Length |
Surface classical slot tube |
Surface new High Flow® filter |
Advantage |
68/55 mm |
68/55 + 40 mm |
250 mm |
0,048 m2 |
0,079 m2 |
65% |
90/65 mm |
90/55 + 50 mm |
500 mm |
0,121 m2 |
0,193 m2 |
60% |
90/70 mm |
90/70 + 60 mm |
400 mm |
0,101 m2 |
0,176 m2 |
74% |