Standard tolerances Gap opening filter tubes
11USR / 12USR / 18USR / 22USR (50 μ and larger) |
|
+/- 20 μ |
80 % |
+/- 30 μ |
15% |
+/- 50 μ |
5% |
11UHR / 12UHR / 105UHR / 11UV / 12UV (20 μ and larger) |
|
+/- 10 μ |
80 % |
+/- 15 μ |
15% |
+/- 20 μ |
4% |
+/- 30 μ |
1% |
111US (10 μ and larger) |
|
+/- 10 μ |
80 % |
+/- 15 μ |
15% |
+/- 20 μ |
4% |
+/- 30 μ |
1% |
11US / 12US (25 μ and larger) |
|
+/- 15 μ |
80 % |
+/- 25 μ |
15% |
+/- 30 μ |
4% |
+/- 50 μ |
1% |
Standard tolerances Length of filter tubes
MAX. LENGTH FILTER TUBES |
|
Dia. (mm) |
Max. length (mm) |
Ø20 - Ø30 |
1600 |
Ø31 - Ø57 |
2400 |
Ø58 - Ø110 |
2700 |
Ø111 - Ø405 |
4700 |
Special lengths on request
TOLERANCES ON LENGTH FILTER TUBES |
|
Dia. (mm) |
Tolerance (mm) |
< Ø164 |
+/- 1 |
> Ø164 |
+/- 2 |
Special tolerances on request
Standard tolerances Diameter filter tubes
TOLERANCES ON DIAMETER FILTER TUBES |
|
Dia. (mm) |
Tolerance (mm) |
Ø23 - Ø110 |
+/- 0,3 |
Ø111 - Ø164 |
+/- 0,5 |
Ø165 - Ø268 |
+/- 1 |
Ø269 - Ø406 |
+/- 2,5 |
Special tolerances on request
Standard tolerances grids
TOLERANCES ON GAP OPENING GRIDS |
|
+/- 50 μ |
95 % |
+/- 100 μ |
5% |
TOLERANCES ON LENGTH AND WIDTH GRIDS |
|
Lengte (mm) |
Tolerance (mm) |
0 - < 1000 |
+/- 2 |
> 1000 - < 1500 |
+/- 3 |
TOLERANCES ON EVENNESS GRIDS |
|
L x B (mm) |
Tolerantie (mm) |
1500 x 1500 |
+/- 5 |
Standard tolerances cylinders
TOLERANCES ON GAP OPENING CYLINDERS |
|
+/- 50 μ |
95 % |
+/- 100 μ |
5% |
Special tolerances on request
TOLERANCES ON DIAMETER CYLINDERS (made directly on machine) |
|
Inner dia. (mm) |
Tolerance (mm) |
Max. Ø 150 |
+/- 0,5 |
TOLERANCES ON DIAMETER CYLINDERS (with longitudinal seam) |
|
Inner dia. (mm) |
Tolerance (mm) |
> Ø150 - Ø200 |
+/- 1 |
Ø201 - Ø300 |
+/- 1,5 |
Ø301 - Ø600 |
+/- 2 |